After doing so, the heater started up just fine for about a week. JANDY 200 INSTALLATION AND OPERATION MANUAL Pdf Download It could be something silly like a stick or acorn is stuck in it's intake. I am having the same issue, but if I remove the yellow wire from the pressure sensor the fault light on the igniter comes on any ideas? Check the fuse or reset the breaker. I was reading through this wiring diagram from the manual. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Performance & security by Cloudflare. Easy replacement. The reading should be between 5 and 10 A. Hi there, FAULT - CHECK IGN STEPS Causes: 1.Broken, split, pinched or disconnected fan/switch tubing.2.Fan not operating.3.Fan running slow or premature fan failure.4.Air flow restricted at intake or discharge.5.Oscillating pump pressure.6.Low gas supply pressure.7.No flame at burners. Jandy Pool Heater Wont Ignite [9 Easy Fixes]. Apparently the bracket that holds it rusted and broke in half. Jandy Pro Series JXi Pool Heater Troubleshooting Guide - Doheny The sign next to it says it is an Ignition fault. Look at the top or side of the gas valve for the two wires attached to the solenoid terminals. Our pool is a little over a month old and we have not been able to use the heater yet. You can stop after draining the tank until clean water starts to come out and there is no sputtering. On there is another Y/BK wire which goes to the air flow switch. It is being practiced by thousands of pool owners just like you. From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: how to repair jandy lrz fault check ignitionPearl Wilson: Assistant: I'll do al. Fluctuating Filter Pump Pressure 2. Looking for a Jandy tech in the Western PA (Pittsburgh) area that might be able to help? You need to test the pressure switch for continuity with a multimeter. I was depending on the main regulator at the meter. ILL LET YOU KNOW HOW I MAKE OUT. Connect a multimeter that can measure microamps (A) in series between the sensor terminal and the wire that feeds to the gas valve to see if the flame sensor is delivering a signal to the gas valve. I know you've reported it doesn't light at all but please check again. Oh, and gas valves very rarely go bad. Any ideas where is goes of the part number? It may not display this or other websites correctly. When electrical power is added to the hot surface igniter, it transforms into a crystalline element that gets extremely hot. Powered by Invision Community, Inground, Fiberglass and Aboveground Swimming Pools, Jandy Lxi 250 Heater - Fault Check Ign Control. Open the front panel, remove the internal cover #69, and then remove the single screw affixing the flame sensor rod and detach the electrical connector. Jandy Pro Series JXi Pool Heater Troubleshooting Guide. cant hear the gas valve open and it doesnt ignite. Special Precautions for LP Gas. The heater worked fine last season right before winter. After about four minutes, it shuts off and gives me a "FAULT CHECK IGN CONTROL" message on the display. We have a Jandy LXi 250 heater for our salt water pool. So, your heater wont light up if the airflow is restricted. Faulty Pilot 7. Just because you smell gas, doesn't mean you are getting adequate flow. Your previous content has been restored. Clear editor. Page 1 OPERATION MANUAL Jandy Pro Series Gas-Fired Pool and Spa Heater Models 200, 260, 330, 400 If these instructions are not followed exactly, a fire or explosion may WARNING result, causing property damage, personal injury, or death. You'll hear a loud metallic click when the relay opens the valve. Water Connections. It's well worth a call out charge to have a qualified gas plumber check flow and pressure for you. 8,489 satisfied customers. +1 ignitor most likely I had to replace mine after 1 season. If there are no terminals visible, you may need to remove the cover first. If you replace the ignition module you will need to make sure you get the exact replacement. Note: You can also read how to fix Pentair heater not turning onproblem. But I have gas to the valve, I have checked voltage and resistance everywhere, and its all in range. Your previous content has been restored. Carefully check to be sure no wires came loose and reconnect if they did. I removed the front panel and I see the wiring and boards in there. Jandy Pool Heater Won't Ignite [7 Easy Solutions] - FireplaceHubs Plus, I still haven't gotten a good answer on which need to be hot, which are negative, etc.. Gave it maybe 5-10 minutes. Call for service if the heat pump is still not working. Next time it fails, without doing anything else, check for voltage across the air switch terminals and the water pressure switch terminals. Doheny's DIY Pool Care Help Center. JavaScript is disabled. VOLTAGE GOOD AT EVERY TERMINAL AND SWITCH. You must log in or register to reply here. Locate the hose bib to bleed away air after shutting off the water heater. NOW while we were vacuuming pool I hear 2 big noises like something exploding. Greetings to all, I have a brand-spanking-new Jandy Zodiac LXi 400,000 BTU/HR heater that has never worked. Keep reading our Jandy JXi pool heater troubleshooting guide to get your heater started ASAP. My heater is giving me a code after about one minute of heating up. Next step is the blower itself. I removed the front panel and I see the wiring and boards in there. That's weird. Our installer could not find anything wrong with the unit, so he surmised it was caused by insufficient gas pressure. I am getting the following fault code on my Zodiac Electronic We called the gas company, they installed a larger meter (for free), and the problem never recurred. If it won't turn, the bearings are seized.and the motor will need to be replaced and is something you can do yourself. http://www.northamericahvac.com/servlet/the-5245/Honeywell-Air-Pressure-Switch/Detail. Heres how. Could be a connection issue. . The diagnostic light does not come on. In my case it was the sensor connections on the sensor mounted close to the blower motor that has a soft rubber hose connecting tube. The heater has been giving me a bunch of trouble lately and I was hoping someone here may have some insight. Walked over to heater and it said "CHECK IGN STEPS". It may not display this or other websites correctly. I don't know how to further disassemble my heater to get to where the actual blower is mounted. Can you walk me through the steps? 2,717 satisfied customers. There are many ignition modules used in several industries that range from pools to HVAC to industrial dryers.they all look the same! You should smell gas if it is the ignitor as it tries to light and then gives up. Jandy Pool Heater Won't Ignite [9 Easy Fixes] Jandy JXi 400 Manuals | ManualsLib Connect each tester probe on the multimeter to each of the gas valves terminals. If needed, simply add enough water to your pool to reach the proper levels, and your surge or pump pulsing problem should be resolved in no time. With over 200,000 members, TFP is the largest and most influential pool & spa website on the Internet. This was done for safety and to be sure wires didn't accidentally come loose and short out which could short out electrical components. I've checked the wires and they all seem fine.With that in mind, if anyone has any ideas, I'd be grateful. October 26, 2021 in All Swimming Pools Types. When that happened, I'd switch it off and back on again and it would run without trouble. Disabled Safety Switches 6. When I try to start it now, the sequence goes like this:1. I would pull the ignitor and inspect it. This means I'm scared of it. Carefully open the lid as the while you are going through the ignition sequence. Hopefully, now you have the answer to your question, Why is my Jandy pool heater not working?. We are a registered 501(c)3 non-profit that is funded by user donations. It will run up from 65-80's with no problem then throws the error consistently at that point. Then the ignitor will time out after 5 sec if the flame sensor does not sense ignition. It may not display this or other websites correctly. Why is my Jandy LXi/JXi heater not turning on w/ automation - Facebook Ensure that youre monitoring the single ohms setting. Home Jandy JXi/LXi Ignition Control Kit | R0456900 Ignition Control For Use With: Model 200, 260, 400 JXi and LXi Low NOx Heaters; Natural & Propane Gas. Subsequent nights it would cut out with CHECK FLOW. If it works then that connection is bad. I got resistance when my booster pump came on and none when it was off, so it is working. PoolSpaForum.com Troubleshooting the burner not staying lit on my Jandy LXI 400K Pool HeaterFenwal Controller, 3 flash lockout: ignition lockoutThis happens when the Fenwal control does not sense a flame during the 7 secondtrial for ignition period or the flame sense signal strength is not strong enough.Troubleshooting as follows:Make sure that the spark rod and flame sense rod are clean. I am having the same problem,Unit is 1 yr old. Twice, though, I noticed it would shut off overnight and give me an ignition control fault message. IPvFletch Could it be the gas pressure valve? There's a round hole that you can put a pencil in the hole to release the latch then swing it out to latch it out about 90 degrees. I keep reading the intake is on the bottom of the heater, but then there's this air pressure slider on the side which is adjustable. I assume they were living in there this past winter. Jandy Lx400 Heater Problems - Won't Light - Pool and Spa Forum Little over 4 years old. The switch is working fine, but the tube that goes around to the side of the unit was off. I could likely test continuity on it if I knew how it worked. Make sure that the vents are not placed beneath decks, stairways, or automobile ports. Jandy JXi/LXi Ignition Control Kit | R0456900 - Pool Supply Unlimited Youll notice a side with different terminals when you turn the pressure switch around. If you have an account, sign in now to post with your account. Serving Monmouth and Ocean counties and The Princeton Route 1 corridor communities. I'll be looking for your post.